<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>22246</ErrorNumber>
<ErrorFamily>Autoloader 2</ErrorFamily>
<ErrorMessage>
ALE2: Picker vacuum cup vacuum is above threshold before plate contact.
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_VLF_Auto</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Check val pvth, and sensor.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Resume if possible, Select media removed,
Check that there is nothing blocking the picker deck plate vacuum cups.
Contact Creo response center.
</text></DescriptionText>
</OperatorAction>
<Cause>
The picker's vacuum cup vacuum was turned on when there should be
no obstruction, but vacuum is above (val pvth).
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/cal_picker.xml</LinkAddress><LinkTitle>Command: cal picker</LinkTitle></Link>
##Commnad:  cal pvth
<Link><LinkAddress>../nvs/val_cfg_pvth.xml</LinkAddress><LinkTitle>NVS: val pvth</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:34:00 2008 PST
</Updated>
<Links>
</Links>
</Error>